Schneider Electric
Primary Air Insulated Switchgear, MCSet 17.5kV, incomer or feeder functional unit, up to 12kV, up to 4000A, 50kA, width 570mm
Primary Air Insulated Switchgear, MCSet 17.5kV, incomer or feeder functional unit, up to 12kV, up to 4000A, 50kA, width 570mm
Couldn't load pickup availability
Description
Description
Specifications
Main
Master range SeT Series
Range of product MCSeT
Product name MCSet 17.5 kV
Device short name AD1C
Functional unit Incomer
Feeder
Product or component type Cubicle
Insulation technology Air insulated switchgear
Number of phases 3
Network type AC
Type of installation Indoor
Busbar system Single busbar
Switching device SF6 contactor
Vacuum contactor
Product compatibility Rollarc
CTV1
Standards IEC 62271-200
Rated voltage (Ur) 12 kV
Rated short-duration power frequency withstand voltage (Ud) / Common value 28 kV
Rated lightning impulse withstand voltage (Up) / Common value 75 kV
Rated frequency (fr) 50/60 Hz
Rated continuous current of busbars (Ir) 4000 A
Rated continuous current (Ir) 400 A contactor only
315 A with fuse at 7.2 kV
200 A with fuse at 12 kV
Rated short-circuit breaking current (Isc) 50 kA with fuse
Rated short-circuit making current 125 kA 50 Hz
130 kA 60 Hz
Rated short-time withstand current (Ik) 50 kA
Rated duration of short-circuit (tk) 3 s
Rated peak withstand current (Ip) 125 kA 50 Hz
130 kA 60 Hz
Loss of service continuity category LSC2B
Internal arc classification AFL
AFLR
Rated arc fault current (IA) 50 kA
Rated arc fault duration (tA) 1 s
Internal arc gas evacuation Upwards inside the room
Upwards outside the room
Partition class PM
Complementary
Degrees of protection provided by enclosures (IP code) IP3X (enclosure)
IP4X (enclosure)
IPX1 (enclosure)
IPX2 (enclosure)
IP2XC (between compartments)
Degree of protection of enclosure against external mechanical impacts (IK code) IK07
Instrument transformer Current transformer
Surge arrester
Sensor type TH110 thermal sensor
CL110 environmental sensor
PD100 partial discharges monitoring solution
Voltage presence type VPIS voltage presence indicating system
VDIS voltage detecting and indicating system
Protection relay Easergy P3
Easergy P5
Easergy Sepam series 60
Easergy Sepam series 80
Arc fault detector Easergy Vamp 125
Cable type Single core
Three core
Cable cross-section 630 mm² single core
240 mm² three core
Number of cables per phase Up to 3
Mass 850 kg
Height 2300 mm
2770 mm (tunnel with external exhaust)
2770 mm (tunnel with internal exhaust)
2530 mm (compact tunnel with internal exhaust)
Width 570 mm
Depth 1550 mm (AFL)
1725 mm (AFLR)
Environment
Ambient air temperature for operation -5…40 °C
Ambient air temperature for storage -25…55 °C
Humidity conditions Average relative humidity over 24 h <= 95 %
Average relative humidity over 1 month <= 90 %
Operating altitude <= 1000 m
Share

Frequently Asked Questions
How do I choose the right battery for my needs?
Check voltage, capacity, size, and power requirements. If you’re unsure, our support team can help you select the most suitable option.
Do batteries require regular maintenance?
Many modern batteries are maintenance-free. However, proper charging and storage can significantly extend battery life.
What should I do if my battery is not performing properly?
Check connections, charging conditions, and usage. If the issue continues, contact our support team for assistance.
Do temperature conditions affect battery performance?
Yes, extreme heat or cold can impact performance and lifespan. Storing and using batteries within recommended temperature ranges is important.
Can I get help if I’m unsure about compatibility?
Absolutely. Our experts are available to guide you and ensure you choose a battery that fits your requirements perfectly.