Master range SeT Series
Range of product MCSeT
Product name MCSet 17.5 kV
Device short name CL3
Functional unit Line up bus sectioning
Product or component type Cubicle
Insulation technology Air insulated switchgear
Number of phases 3
Network type AC
Type of installation Indoor
Busbar system Single busbar
Switching device Vacuum circuit breaker
Product compatibility EasyPact EXE
Standards IEC 62271-200
Rated voltage (Ur) 17.5 kV
Rated short-duration power frequency withstand voltage (Ud) / Common value 38 kV
Rated lightning impulse withstand voltage (Up) / Common value 95 kV
Rated frequency (fr) 50/60 Hz
Rated continuous current of busbars (Ir) 4000 A
Rated continuous current (Ir) 1250 A
2500 A
3150 A
4000 A
Rated short-circuit breaking current (Isc) 50 kA
Rated short-circuit making current 125 kA 50 Hz
130 kA 60 Hz
Rated short-time withstand current (Ik) 50 kA
Rated duration of short-circuit (tk) 3 s
Rated peak withstand current (Ip) 125 kA 50 Hz
130 kA 60 Hz
Loss of service continuity category LSC2B
Internal arc classification AFL
AFLR
Rated arc fault current (IA) 50 kA
Rated arc fault duration (tA) 1 s
Internal arc gas evacuation Upwards inside the room
Upwards outside the room
Partition class PM
Complementary
Degrees of protection provided by enclosures (IP code) IP3X (enclosure)
IP4X (enclosure)
IPX1 (enclosure)
IPX2 (enclosure)
IP2XC (between compartments)
Degree of protection of enclosure against external mechanical impacts (IK code) IK07
Instrument transformer Current transformer
Voltage transformer
Surge arrester
Sensor type TH110 thermal sensor
CL110 environmental sensor
PD100 partial discharges monitoring solution
Voltage presence type VPIS voltage presence indicating system
VDIS voltage detecting and indicating system
Protection relay Easergy P3
Easergy P5
Easergy Sepam series 60
Easergy Sepam series 80
Arc fault detector Easergy Vamp 125
Mass 1310 kg
Height 2300 mm
2530 mm (compact tunnel with internal exhaust)
2770 mm (tunnel with external exhaust)
2770 mm (tunnel with internal exhaust)
Width 900 mm
Depth 1550 mm (AFL)
1725 mm (AFLR)
Environment
Product certifications Bureau Veritas (BV) Marine
DNV Marine
American Bureau of Shipping (ABS) Marine
Lloyd’s Register (LR) Marine
Ambient air temperature for operation -5…40 °C
Ambient air temperature for storage -25…55 °C
Humidity conditions Average relative humidity over 24 h <= 95 %
Average relative humidity over 1 month <= 90 %
Operating altitude <= 1000 m
Share

Frequently Asked Questions
How do I choose the right battery for my needs?
Check voltage, capacity, size, and power requirements. If you’re unsure, our support team can help you select the most suitable option.
Do batteries require regular maintenance?
Many modern batteries are maintenance-free. However, proper charging and storage can significantly extend battery life.
What should I do if my battery is not performing properly?
Check connections, charging conditions, and usage. If the issue continues, contact our support team for assistance.
Do temperature conditions affect battery performance?
Yes, extreme heat or cold can impact performance and lifespan. Storing and using batteries within recommended temperature ranges is important.
Can I get help if I’m unsure about compatibility?
Absolutely. Our experts are available to guide you and ensure you choose a battery that fits your requirements perfectly.