Schneider Electric
Secondary Gas Insulated Switchgear, Ringmaster AirSeT, 3 functions, NE, FR Standing, 200A
Secondary Gas Insulated Switchgear, Ringmaster AirSeT, 3 functions, NE, FR Standing, 200A
Couldn't load pickup availability
Description
Description
Environmental Data
Use Longer
Repair
No
Main documents
Documents
Specifications
Main
Master range SeT Series
Range of product Ringmaster AirSeT
Product name Ringmaster AirSeT
Number of functions 3
Device short name RN2Air
Functional unit Circuit breaker
Switch disconnector
Type of extensibility NE (non extensible)
Insulation technology Gas insulated switchgear
Sealed pressure system
Type of Insulating gas Pure air
Switching device Load break switch with shunt vacuum interruption (SVI)
Vacuum circuit breaker
Number of phases 3
Network type AC
Type of installation Outdoor
Standards IEC 62271-200
Rated voltage (Ur) 12 kV
Rated short-duration power frequency withstand voltage (Ud) / Common value 38 kV
Rated short-duration power frequency withstand voltage (Ud) / isolating distance 45 kV
Rated lightning impulse withstand voltage (Up) / Common value 95 kV
Rated lightning impulse withstand voltage (Up) / Across the isolating distance 110 kV
Operating voltage 3.3 kV
6.6 kV
11 kV
Rated frequency (fr) 50 Hz
Rated continuous current of busbars (Ir) 630 A
Rated continuous current (Ir) 630 A
Rated short-circuit breaking current (Isc) 21 kA
Rated short-circuit making current 52.5 kA 50 Hz
Rated short-time withstand current (Ik) 21 kA
Rated duration of short-circuit (tk) 3 s
Rated peak withstand current (Ip) 52.5 kA
Filling level for insulation and/or switching (Pre rel.) 0.1 MPa
Minimum functional level for insulation and/or switching (Pme rel.) 0.09 MPa
Loss of service continuity category LSC2
Internal arc classification AF
AFLR
Rated arc fault current (IA) 21 kA
Rated arc fault duration (tA) 1 s
Internal arc gas evacuation Rear exhaust
Arc fault mitigation device Without
Partition class PM
Complementary
Rated supply voltage of auxiliary and control circuits (Ua) 24 V DC
Degrees of protection provided by enclosures (IP code) IP54
Degree of protection of enclosure against external mechanical impacts (IK code) IK10
Pressure sensor type Manometer compensated in altitude and temperature
Manometer compensated with auxiliary contact
Voltage presence type VDIS voltage detecting and indicating system
VDIS VO voltage detecting and indicating system
Bushing type Type C
cable entry Bottom entry
Cable type Single core
Three core
Cable clamp type Metal
Plastic
Cable testing device With integrated cable test facility (iCTF)
Cable cross-section 600 mm²
300 mm²
Number of cables per phase 1
Classification for number of mechanical operations M1 circuit breaker
M2 switch-disconnector
M0 disconnector
M1 earthing switch
Number of mechanical operations 2000 operating cycles circuit breaker
5000 operating cycles switch-disconnector
1000 operating cycles disconnector
2000 operating cycles earthing switch
Rated operating sequence O - 3 min - CO - 3 min - CO
Classification for electrical endurance E2 circuit breaker
E3 switch-disconnector
E2 earthing switch
Number of CO operations at rated continuous current 2
Number of operations at short-circuit making current 10 switch-disconnector
5 earthing switch
Type of operating mechanism (I) CDT
(D) CDT
(B) CDT
Auxiliary contact composition 2 NO/NC
Protection relay Time Limit Fuse (TLF)
VIP 400
VIP 410A
VIP 45
Functional interlock Standard
Interlocking type Without
Fuse type HRC fuse
Mass 600 kg
Height 1800 mm
Width 890 mm
Depth 920 mm
Environment
Ambient air temperature for operation -25…40 °C
Ambient air temperature for storage -40…60 °C
Humidity conditions Average relative humidity over 24 h <= 95 %
Average relative humidity over 1 month <= 90 %
Operating altitude <= 1000 m
Environmental Data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.
Environmental Data explained
How we assess product sustainability
Environmental footprint
Environmental Disclosure
Product Environmental Profile
Use Better
Materials and Substances
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
REACh Regulation
REACh Declaration
Use Longer
Lifetime extension
Repair
No
Use Again
Repack and remanufacture
End of life manual availability
End of Life Information
Documents
Filter by
8 Results
Document Category
Catalogs & Brochures (2)
Conformity Assessments (1)
Installation & User Guides (1)
Sustainability (4)
Language
English (8)
All languages
AirSeT Series Ringmaster AirSeT Secondary Gas Insulated Switchgear Up to 12 kVIndoor/Outdoor Switchgear – Installation, Operation, and Maintenance Manual (01)
PDF (281.6 MB) | 11 Dec 2025 | User guide
RMZDQ3FFR REACh Declaration
PDF (195.3 KB) | 02 Jan 2026 | Declaration of Conformity (Sustainability) - REACh Declaration
RMZDQ3FFR EU RoHS Declaration
PDF (195.3 KB) | 02 Jan 2026 | Declaration of Conformity (Sustainability) - EU RoHS Declaration
Ringmaster AirSeT - RN2Air (1.0)
PDF (544.6 KB) | 16 Jun 2025 | Circularity Profile - End of Life Instructions
Ringmaster AirSeT - RN2Air (1.0)
PDF (408.4 KB) | 16 Jun 2025 | Environmental Disclosure - Product Environmental Profile
RingmasterAirSeT3 Function declaration of conformity (1.0)
PDF (504.6 KB) | 04 Jun 2025 | Declaration of conformity - EU/CE
Ringmaster AirSeT Catalogue (1.0)
PDF (14.5 MB) | 21 May 2025 | Catalog
Ringmaster AirSeT eBrochure (1.0)
PDF (48.3 MB) | 23 Oct 2024 | Brochure
Share

Frequently Asked Questions
How do I choose the right battery for my needs?
Check voltage, capacity, size, and power requirements. If you’re unsure, our support team can help you select the most suitable option.
Do batteries require regular maintenance?
Many modern batteries are maintenance-free. However, proper charging and storage can significantly extend battery life.
What should I do if my battery is not performing properly?
Check connections, charging conditions, and usage. If the issue continues, contact our support team for assistance.
Do temperature conditions affect battery performance?
Yes, extreme heat or cold can impact performance and lifespan. Storing and using batteries within recommended temperature ranges is important.
Can I get help if I’m unsure about compatibility?
Absolutely. Our experts are available to guide you and ensure you choose a battery that fits your requirements perfectly.